Roofing Systems

Roofing Systems Reference

A comprehensive guide to every major roofing system used in Oklahoma — from residential asphalt shingles to commercial membrane systems and metal roofing — with specifications, code references, and Oklahoma-specific installation considerations.

Most Common ResidentialSteep-Slope ResidentialIRC R905.2 / ASTM D3462

Asphalt Shingles

Asphalt shingles are the most widely installed roofing material in Oklahoma, covering the majority of residential structures. Available in three-tab and architectural (laminated) profiles, modern asphalt shingles are manufactured to meet ASTM D3462 standards and are rated for wind resistance, impact resistance, and fire classification.

Technical Specifications

Minimum Slope2:12 with double underlayment; 4:12 standard
Wind RatingClass D (110 mph) to Class H (150 mph) per ASTM D7158
Impact RatingClass 1–4 per UL 2218; Class 4 recommended in Oklahoma hail zones
Fire RatingClass A (most architectural shingles); Class C (three-tab)
Fastening4 nails minimum; 6 nails required in high-wind zones (115 mph+)
UnderlaymentMin. No. 15 felt; self-adhering ice/water shield at eaves and valleys

Oklahoma-Specific Considerations

Oklahoma's hail frequency makes Class 4 impact-resistant shingles the strongly recommended choice for residential roofing. Many insurance carriers offer premium discounts for Class 4 shingles. In wind zones above 130 mph (southwestern Oklahoma), architectural shingles with a minimum Class H wind rating are required. FORTIFIED Roof designation requires Class 4 impact resistance and enhanced fastening.
Commercial Flat RoofingLow-Slope / Flat CommercialIBC 1507.12 / ASTM D4637

EPDM (Ethylene Propylene Diene Monomer)

EPDM is a synthetic rubber membrane widely used on low-slope commercial and industrial roofs. Available in 45-mil and 60-mil thicknesses, EPDM is installed in fully adhered, mechanically attached, or ballasted configurations. It is highly resistant to UV degradation, ozone, and extreme temperature fluctuations, making it well-suited to Oklahoma's climate.

Technical Specifications

Minimum Thickness45 mil (mechanically attached/ballasted); 60 mil (fully adhered)
Maximum SlopeDesigned for slopes up to 2:12; above 2:12 requires special detailing
Temperature Range-40°F to 300°F service range
Seam MethodLap seam with EPDM tape or liquid adhesive; minimum 3-inch overlap
Fire RatingClass A with approved cover board and insulation assembly
Wind UpliftFM 1-60 to 1-90 depending on attachment method and fastener spacing

Oklahoma-Specific Considerations

EPDM performs well in Oklahoma's temperature extremes. Ballasted EPDM is not recommended in high-wind zones without supplemental mechanical attachment at perimeters and corners. Seam integrity is critical — Oklahoma's thermal cycling stresses lap seams; 60-mil fully adhered systems are preferred for long-term performance. EPDM is black and absorbs heat; white-coated or TPO systems may be preferred for energy efficiency in Oklahoma's hot summers.
Energy-Efficient Flat RoofingLow-Slope / Flat CommercialIBC 1507.15 / ASTM D6878

TPO (Thermoplastic Polyolefin)

TPO is a single-ply thermoplastic membrane that has become the most widely installed commercial roofing membrane in the United States. Available in white, gray, and tan, TPO's reflective surface reduces cooling loads significantly. Seams are heat-welded, creating a monolithic waterproof bond stronger than the membrane itself when properly executed.

Technical Specifications

Minimum Thickness45 mil (standard); 60 mil and 80 mil available for enhanced durability
Seam MethodHot-air welded; minimum 1.5-inch weld width; field-tested with probe
Solar ReflectanceWhite TPO: SRI 104+ (ENERGY STAR qualified)
Fire RatingClass A with approved assembly
Wind UpliftFM 1-60 to 1-120 depending on attachment; perimeter/corner enhanced fastening required
IECC ComplianceWhite TPO meets IECC 2021 cool roof requirements for Climate Zone 3 (Oklahoma)

Oklahoma-Specific Considerations

TPO is the preferred commercial membrane in Oklahoma for energy efficiency. Oklahoma falls in IECC Climate Zone 3 (south) and Zone 4 (north), where cool roofs provide measurable energy savings. TPO weld quality is critical — Oklahoma's temperature swings stress seams; welds must be tested with a probe immediately after installation and again after the first thermal cycle. Mechanically attached TPO in Oklahoma's high-wind zones requires enhanced perimeter and corner fastening per FM Global data sheets.
Multi-Ply MembraneLow-Slope Commercial & ResidentialIBC 1507.11 / ASTM D6163 / ASTM D6164

Modified Bitumen (Mod-Bit)

Modified bitumen is an asphalt-based membrane reinforced with polyester or fiberglass and modified with APP (atactic polypropylene) or SBS (styrene-butadiene-styrene) polymers. Applied in two-ply systems (base sheet + cap sheet), mod-bit provides excellent waterproofing, puncture resistance, and UV stability. Installation methods include torch-applied, cold-applied adhesive, and self-adhering.

Technical Specifications

Membrane TypesAPP (torch-applied, UV stable); SBS (cold-applied or torch, flexible in cold)
System Configuration2-ply minimum: base sheet (ASTM D4601) + cap sheet (ASTM D6163/D6164)
Minimum Slope1/4:12 with positive drainage; 1/8:12 with tapered insulation
Surface OptionsGranule-surfaced (UV protection); smooth (requires coating); aluminum-faced
Fire RatingClass A with approved base sheet and cover board assembly
Torch SafetyNRCA torch-applied guidelines; fire watch required; permit required in most jurisdictions

Oklahoma-Specific Considerations

Modified bitumen is widely used on Oklahoma commercial buildings, churches, schools, and low-slope residential additions. SBS-modified systems are preferred in northeastern Oklahoma where winter temperatures can drop below 0°F — SBS remains flexible in cold while APP can crack. Torch-applied systems require a fire watch and fire extinguisher on site; many Oklahoma jurisdictions require a hot-work permit. Granule-surfaced cap sheets are strongly recommended in Oklahoma to resist UV degradation and hail impact.
Exposed Fastener MetalCommercial & AgriculturalIBC 1507.4 / ASTM A653 / ASTM A792

Metal Roofing — R-Panel

R-Panel (also called PBR Panel) is a structural standing-rib metal roofing and wall panel with exposed fasteners. The panel features a major rib at 12-inch spacing with a 1.25-inch rib height, providing structural spanning capability. R-Panel is the most common metal roofing system for agricultural buildings, warehouses, churches, and light commercial construction in Oklahoma.

Technical Specifications

Panel Profile12-inch rib spacing; 1.25-inch rib height; 36-inch coverage width
Gauge26 gauge standard; 24 gauge for longer spans or higher wind zones
Minimum Slope1:12 with sealant tape at laps; 2:12 recommended minimum
FastenersSelf-drilling screws with EPDM washers at 12-inch spacing in field; 6-inch at laps
CoatingsGalvalume substrate; Kynar 500 / PVDF topcoat for 40-year color warranty
Wind RatingFM 1-60 to 1-90 depending on gauge, span, and fastener pattern

Oklahoma-Specific Considerations

R-Panel is the dominant roofing system for Oklahoma agricultural and light commercial construction. EPDM washer screws must be torqued correctly — over-torquing compresses the washer and creates a leak point; under-torquing allows panel movement and washer failure. In Oklahoma's high-wind zones, 24-gauge panels with reduced fastener spacing are required. Galvalume substrate is strongly preferred over galvanized for Oklahoma's climate — galvanized panels show rust bleed at cut edges within 5–10 years in humid eastern Oklahoma.
Corrugated Metal PanelAgricultural & ResidentialIBC 1507.4 / ASTM A653

Metal Roofing — AG Panel

AG Panel (Agricultural Panel) is a corrugated metal roofing panel with a 2.67-inch corrugation pattern and exposed fasteners. Lighter and less expensive than R-Panel, AG Panel is used primarily for agricultural buildings, barns, sheds, and budget residential applications. It is not a structural panel and requires closer purlin spacing than R-Panel.

Technical Specifications

Panel Profile2.67-inch corrugation; 26-inch coverage width
Gauge29 gauge standard; 26 gauge for residential or higher-wind applications
Minimum Slope3:12 recommended; 2:12 with sealant tape at all laps
Purlin Spacing24 inches maximum for 29 gauge; 36 inches for 26 gauge
FastenersSelf-drilling screws with EPDM washers; fastened at every corrugation at laps
ApplicationsAgricultural buildings, barns, sheds, carports, budget residential re-roofing

Oklahoma-Specific Considerations

AG Panel is widely used across rural Oklahoma for agricultural structures. It is not recommended for occupied residential structures in Oklahoma's high-wind zones without engineering review — 29-gauge AG Panel has limited wind uplift resistance. For residential applications, 26-gauge AG Panel with a 3:12 minimum slope and enhanced fastening is the minimum acceptable standard. AG Panel is not suitable for commercial occupied buildings without a stamped engineering letter confirming the panel meets the design wind pressures for the project location.
Concealed Fastener MetalResidential & Commercial PremiumIBC 1507.4 / ASTM A792 / ANSI/SPRI ES-1

Metal Roofing — Standing Seam

Standing seam metal roofing uses concealed fastener clips that allow the panel to float and expand/contract with temperature changes. The raised seam (1.5 to 2 inches) is mechanically seamed or snap-locked, creating a continuous waterproof joint with no exposed fasteners. Standing seam is the highest-performance metal roofing system available and is the preferred choice for Oklahoma's demanding climate.

Technical Specifications

Seam TypesSnap-lock (residential); mechanical 360° double-lock seam (commercial/high-wind)
Panel Width12 to 18 inches typical; 16-inch most common
Gauge24 gauge standard; 22 gauge for commercial; 26 gauge for budget residential
Minimum Slope1:12 for snap-lock; 1/4:12 for structural standing seam with engineering
Wind RatingFM 1-90 to 1-180 with floating clips; highest wind resistance of any metal system
Thermal MovementFloating clips allow full thermal movement; no fastener pullout or oil-canning

Oklahoma-Specific Considerations

Standing seam is the recommended metal roofing system for all occupied structures in Oklahoma's high-wind zones. The concealed clip system eliminates the primary failure mode of exposed fastener panels — washer degradation and fastener pullout. Mechanical 360° seam systems are required for FM 1-90+ ratings needed in southwestern Oklahoma. Standing seam is FORTIFIED-compatible and is the metal system of choice for FORTIFIED Roof designation. For Oklahoma's 120°F+ temperature range, 24-gauge steel with PVDF coating and floating clips is the standard specification.
Roof Restoration SystemRestoration & MaintenanceIBC 1507.16 / ASTM D6083 / ASTM D6694

Roofing Coatings

Roofing coatings are fluid-applied membranes used to restore, waterproof, and extend the service life of existing roofing systems. Common types include elastomeric acrylic, silicone, polyurethane, and aluminum-asphalt coatings. Coatings are not a replacement for a structurally failed roof — they are a maintenance and restoration tool for roofs that are structurally sound but showing surface degradation, minor cracking, or reduced reflectivity. When properly applied to a prepared substrate, a quality coating system can add 10–15 years of service life and significantly reduce cooling loads.

Technical Specifications

Coating TypesElastomeric acrylic (ASTM D6083); silicone (ASTM D6694); polyurethane; aluminum-asphalt (ASTM D2824)
Application Rate1.0–1.5 gal/sq (base coat); 1.0–1.5 gal/sq (top coat); total 2.0–3.0 gal/sq typical
Minimum Dry Film20 mils DFT minimum for warranted systems; verify per manufacturer spec sheet
Substrate CompatibilityEPDM, TPO, mod-bit, metal, SPF, built-up roofing; not for asphalt shingles
Solar ReflectanceWhite elastomeric/silicone: SRI 90–110; ENERGY STAR qualified products available
Code ReferenceIBC Section 1507.16 (liquid-applied roofing); re-roofing provisions under IBC 1511 apply

Oklahoma-Specific Considerations

Roofing coatings are widely used in Oklahoma on commercial flat roofs — EPDM, TPO, mod-bit, and metal — to restore waterproofing and improve energy performance. Oklahoma's intense UV exposure and temperature swings (−10°F to 115°F+) accelerate surface degradation on low-slope membranes; a quality silicone or elastomeric acrylic coating can reset the clock on an otherwise sound roof. For homeowners: coatings are not appropriate for asphalt shingle roofs and are not a substitute for replacing a roof that has structural deck damage, multiple leak points, or has exceeded its service life. For contractors: substrate preparation is the most critical step — pressure washing, seam reinforcement with fabric, and primer application are required before coating; a coating applied over a wet or contaminated substrate will fail prematurely. CIB registration is required for all roofing work in Oklahoma, including coating applications on residential structures. Coating systems applied as re-roofing must comply with IBC Section 1511 and OUBCC amendments. Always verify manufacturer warranty requirements — most warranted systems require a manufacturer-approved applicator and a pre-application inspection.