2024 IBC / IRC

Oklahoma Building Code

Oklahoma adopts building codes through the Oklahoma Uniform Building Code Commission (OUBCC). The 2024 International Building Code (IBC) and International Residential Code (IRC) took effect September 14, 2026. All roofing systems on new construction and substantial renovations must comply with these standards as adopted and locally amended.

Adoption Authority

The Oklahoma Uniform Building Code Commission (OUBCC) administers the state building code under Title 59, Section 1000.50 et seq. of the Oklahoma Statutes (the Oklahoma Uniform Building Code Commission Act). OUBCC administrative rules — including adopted code editions and amendments — are published in Oklahoma Administrative Code (OAC) Title 748. Local jurisdictions may adopt amendments but may not reduce minimum standards below the state baseline.

Roofing Material Standards

All roofing materials must be listed and labeled per IRC Section R905 and IBC Section 1507. Approved materials include asphalt shingles (ASTM D3462), metal panels (ASTM A653), tile (ASTM C1167), and modified bitumen membranes (ASTM D6163/D6164).

Underlayment Requirements

IRC R905.1.1 requires a minimum of one layer of No. 15 asphalt-saturated felt underlayment for slopes 4:12 and above. Slopes 2:12 to 4:12 require double underlayment. Ice and water shield is required in valleys and at eaves in areas subject to ice damming.

Flashing Standards

Flashing at all roof penetrations, valleys, and wall intersections must comply with IRC R903.2 and R905.2.8. Corrosion-resistant metal flashing minimum 0.019 inch (26 gauge galvanized) is required at all critical junctions.

Roof Decking

Structural roof sheathing must comply with IRC R803. Minimum 7/16-inch OSB or 15/32-inch plywood is required for most residential applications. Panel edges must be supported by blocking or H-clips at 24-inch spacing.

02
ASCE 7-22 / IRC R301

Wind & Hail Requirements

Oklahoma is located in a high-wind region with design wind speeds ranging from 115 mph to 140 mph depending on county and exposure category. Roofing systems must be designed and installed to resist these loads per ASCE 7-22 and IRC Table R301.2(1).

Design Wind Speed Zones

Oklahoma spans ASCE 7 wind speed zones from 115 mph (Risk Category II) in the Panhandle to 140 mph in the southwestern corner. Contractors must verify the applicable design wind speed for each project location using the ASCE 7 wind speed maps or the Oklahoma-specific maps published by OUBCC.

Enhanced Fastening Schedules

In high-wind zones (115 mph+), asphalt shingles require a minimum 6-nail fastening pattern per ARMA guidelines and IRC R905.2.6. Nails must be minimum 12-gauge, 0.105-inch shank diameter, with a 3/8-inch head, penetrating through the deck a minimum of 3/4 inch.

Impact Resistance Ratings

Oklahoma's hail exposure requires impact-resistant roofing materials in many jurisdictions. Class 4 impact resistance (UL 2218 or FM 4473) is the highest rating available. Some local jurisdictions and insurance carriers encourage or require Class 4 materials, but there is no uniform statewide mandate — verify applicable local ordinances and insurer requirements for each project location. Class 3 is the minimum for most insurance discounts.

Roof-to-Wall Connections

Hurricane straps or equivalent metal connectors are required in wind zones above 130 mph per IRC R802.11. Minimum H2.5A or equivalent connector providing 250 lb uplift resistance per rafter or truss is required. Connections must be inspected prior to sheathing installation.

Exposure Categories

Exposure Category B (suburban/wooded), C (open terrain), and D (coastal/open water) affect design wind pressure calculations. Most Oklahoma locations are Exposure B or C. Contractors must correctly identify the exposure category for each project to apply the correct pressure coefficients.

03
IBHS 2020 Edition

FORTIFIED Residential Standards

The IBHS FORTIFIED Home program establishes above-code construction standards for Oklahoma residences. Three designation levels — FORTIFIED Roof, FORTIFIED Silver, and FORTIFIED Gold — provide progressively stronger protection against Oklahoma's severe weather events.

FORTIFIED Roof Designation

The entry-level designation focuses on the roof system — the most vulnerable component in Oklahoma storms. Requirements include: sealed roof deck (self-adhering underlayment or taped sheathing joints), enhanced attachment of roof covering, and proper drip edge installation. This designation alone can qualify homeowners for significant insurance discounts.

FORTIFIED Silver Designation

Silver builds on FORTIFIED Roof by adding requirements for opening protection (windows, doors, skylights) and garage doors rated for high-wind loads. All openings must meet ASTM E1886/E1996 or equivalent impact and pressure standards.

FORTIFIED Gold Designation

The highest designation adds continuous load path requirements — a complete structural connection from roof to foundation. This includes roof-to-wall connectors, wall-to-floor connections, and floor-to-foundation anchoring, creating a fully integrated structural system.

Oklahoma-Specific Requirements

Oklahoma FORTIFIED projects must use materials listed on the IBHS Accepted Products list. The sealed roof deck requirement uses a minimum 4-inch-wide self-adhering modified bitumen tape at all sheathing joints, or a fully adhered self-adhering underlayment over the entire deck surface.

Evaluation & Documentation

FORTIFIED designation requires evaluation by an IBHS-approved FORTIFIED Evaluator. The evaluator inspects the installation at key stages and submits documentation to IBHS for designation issuance. Designations are valid for 5 years and must be renewed upon re-roofing.

04
HAAG Engineering

HAAG Certified Inspector Standards

HAAG Engineering's certification programs establish the professional standard for wind and hail damage assessment on residential and commercial roofing systems. HAAG Certified Inspectors are recognized by insurance carriers, courts, and building officials as qualified experts in storm damage evaluation.

HAAG Certified Inspector — Residential Roofs

The HAAG Certified Inspector (Residential Roofs) credential covers damage assessment methodology for asphalt shingles, wood shakes, tile, metal, and low-slope systems on residential structures. Certification requires passing a written examination and demonstrating field competency in identifying hail impact marks, wind damage patterns, and pre-existing deterioration.

HAAG Certified Inspector — Commercial Roofs

The commercial certification covers built-up roofing, single-ply membranes (TPO, EPDM, PVC), modified bitumen, and metal panel systems. Inspectors learn to distinguish storm damage from manufacturing defects, installation errors, and normal weathering — critical for accurate insurance claims.

Damage Assessment Methodology

HAAG methodology requires systematic inspection of the entire roof surface, documentation of hail impact density and size, measurement of dent depth on metal components, and evaluation of granule loss patterns on asphalt shingles. Inspectors must document findings with photographs, measurements, and written reports meeting insurance carrier standards.

Hail Size & Damage Thresholds

HAAG standards define functional damage thresholds: asphalt shingles require hail of 1 inch or larger to cause functional damage in most cases; metal panels show measurable denting at 3/4 inch; tile and slate may fracture at smaller sizes depending on impact angle and material condition. Age and condition of the roof affect damage susceptibility.

Oklahoma Application

Oklahoma's severe hail climate — averaging over 100 significant hail events annually — makes HAAG certification particularly valuable for contractors and adjusters working in the state. HAAG-certified inspectors are frequently called upon as expert witnesses in insurance disputes and litigation involving storm damage claims.

05
OUBCC Reference

IRC / IBC Code Adoptions & Amendments

Oklahoma's building code adoption history, the specific OUBCC amendments that affect roofing design and installation statewide, and how local jurisdictions may layer additional requirements on top of the state baseline. The 2024 IBC and IRC took effect September 14, 2026; the prior cycle was the 2018 editions.

Current Adopted Codes

Oklahoma currently enforces the 2024 International Building Code (IBC) and 2024 International Residential Code (IRC) as adopted by the OUBCC, effective September 14, 2026. The 2024 International Energy Conservation Code (IECC), International Fire Code (IFC), and International Mechanical Code (IMC) are also in effect and carry roofing-related provisions. Note: the prior cycle was the 2018 IBC (effective September 14, 2021) and 2018 IRC (effective September 14, 2022) — contractors should confirm which edition applies to projects permitted before September 14, 2026.

Oklahoma Amendments to the IRC

The OUBCC has adopted state-specific amendments to the IRC. Key roofing amendments include: modified wind speed maps reflecting Oklahoma-specific data from ASCE 7, enhanced fastening requirements in designated high-wind counties (minimum 6-nail pattern in zones above 115 mph), and clarifications to the FORTIFIED program's relationship to code compliance. Amendments are published in the Oklahoma Administrative Code (OAC) Title 748.

Oklahoma Amendments to the IBC

IBC amendments adopted by Oklahoma address commercial roofing system design, including modified wind uplift pressure requirements for Exposure C and D sites, enhanced parapet and edge metal attachment standards, and requirements for rooftop equipment screening and structural support. Commercial re-roofing triggers full code compliance for the affected roof area under IBC Section 1511.

Local Jurisdiction Amendments

Oklahoma City, Tulsa, Norman, Edmond, and other municipalities may adopt local amendments that are more stringent than the state baseline. As of the 2024 code cycle, neither Oklahoma City nor Tulsa has enacted a municipal ordinance specifically mandating Class 4 impact-resistant shingles (UL 2218) for all roofing — the Class 4 requirement in both metros is driven primarily by insurance carrier underwriting guidelines and IBHS FORTIFIED program requirements, not city code. Contractors must verify current local amendments and insurer requirements for each project jurisdiction. The OUBCC maintains a registry of local amendments at oubcc.ok.gov. If a carrier or HOA requires Class 4, that requirement governs regardless of whether a municipal ordinance exists.

Re-Roofing vs. New Construction

IRC Section R907 governs re-roofing in Oklahoma. Under R907.3, a maximum of two layers of asphalt shingles are permitted before full tear-off is required — a third layer is not allowed. The OUBCC amendments to the IRC (OAC Title 748, Chapter 5) address wind resistance, fastening schedules, and underlayment requirements but do not impose a blanket statewide tear-off mandate beyond the base IRC two-layer limit. Full tear-off is required when: (1) the existing roof already has two layers of shingles, (2) the existing deck is deteriorated, structurally deficient, or shows evidence of moisture damage, or (3) the new roofing system requires a solid substrate not achievable over the existing assembly. Re-roofing must comply with current code requirements for fastening, underlayment, and flashing regardless of whether it is a tear-off or overlay. Always inspect the deck condition before advising a client on overlay vs. tear-off — a structurally compromised deck requires tear-off and repair regardless of layer count.

Permit & Inspection Requirements

A building permit is required for all roofing work in Oklahoma except for minor repairs under a defined threshold (typically less than 25% of the total roof area in a 12-month period). Permitted work requires a final inspection by the authority having jurisdiction (AHJ). Contractors must be registered with the CIB before pulling permits for residential roofing work.

Roof Drainage — IRC R903 & IBC 1502

IRC R903.4 and IBC Section 1502 require positive drainage on all roof systems. Flat and low-slope roofs must drain to internal drains, scuppers, or gutters within 48 hours of rainfall. Secondary (emergency) overflow drains or scuppers are required on all low-slope roofs to prevent ponding loads from exceeding structural capacity. Overflow drains must be sized per IPC Table 1106.2.

Attic Ventilation — IRC R806

IRC R806 requires a minimum net free ventilation area of 1/150 of the attic floor area, reducible to 1/300 when at least 40% of ventilation is provided in the upper portion of the attic. Proper attic ventilation is critical in Oklahoma's climate to prevent moisture accumulation, ice damming in northern counties, and heat buildup that accelerates shingle degradation. Ridge vents, soffit vents, and power ventilators must be balanced and unobstructed.

06
IFC / IECC / IMC / OSHA

Other Codes Affecting Roofing

Beyond the IBC and IRC, several additional codes and regulations directly govern roofing work in Oklahoma — covering energy performance, fire resistance, mechanical penetrations, and worker safety. Compliance with all applicable codes is required; the most restrictive provision governs.

IECC — Energy Code Roofing Requirements

The International Energy Conservation Code (IECC) governs thermal performance of the roof assembly. Oklahoma falls in Climate Zones 3 (most of the state) and 4 (northeastern counties). Zone 3 requires minimum R-38 insulation in attic assemblies (R-49 for Zone 4). Low-slope commercial roofs must meet minimum R-20 continuous insulation or R-20 + R-3.8 ci. Cool roof requirements (minimum SRI of 78 for low-slope, 29 for steep-slope) apply to commercial buildings in Climate Zone 3 under IECC C402.3.

IFC — Fire Code Roofing Requirements

The International Fire Code (IFC) Section 315 and IBC Chapter 15 establish fire resistance requirements for roofing assemblies. Oklahoma requires Class A, B, or C fire-rated roofing depending on occupancy and construction type. Class A is required for most commercial occupancies and high-density residential. Asphalt shingles must carry a UL 790 or ASTM E108 fire rating. Rooftop photovoltaic systems must comply with IFC Section 1204, including required access pathways and setbacks for firefighter access.

IMC — Mechanical Penetrations & Equipment

The International Mechanical Code (IMC) governs all HVAC equipment, exhaust fans, and ductwork penetrations through the roof assembly. IMC Section 304 requires rooftop equipment to be installed on curbs or supports that maintain the integrity of the roofing membrane. All penetrations must be flashed per manufacturer specifications and IRC/IBC flashing requirements. Condensate drain lines must be routed to prevent ice damming and must not discharge onto roof surfaces in a manner that causes ponding.

IPC — Plumbing Penetrations & Roof Drains

The International Plumbing Code (IPC) governs plumbing vent stacks, roof drains, and overflow drains. IPC Section 904 requires all plumbing vent pipes to extend a minimum of 6 inches above the roof surface and be flashed with lead, copper, or approved synthetic boot flashings. Roof drain sizing must comply with IPC Table 1106.2 based on rainfall intensity for the project location. Oklahoma City and Tulsa design rainfall rates are 4.0 inches/hour and 3.8 inches/hour respectively for a 1-hour, 100-year storm event.

OSHA — Roofing Safety Standards

OSHA 29 CFR 1926 Subpart R governs fall protection for roofing work. Oklahoma enforces federal OSHA standards through the Oklahoma Department of Labor. Key requirements: fall protection is required for all roofing work on slopes 4:12 or greater at heights of 6 feet or more above a lower level. Acceptable systems include guardrails, personal fall arrest systems (PFAS), or safety nets. Warning line systems may be used on low-slope roofs (less than 4:12) in combination with a safety monitoring system. Contractors must maintain a written fall protection plan on site.

OSHA — Ladder & Access Safety

OSHA 29 CFR 1926.1053 governs ladder safety for roofing access. Extension ladders must extend a minimum of 3 feet above the roof edge and be secured at the top. Ladder angle must be 1:4 (one foot out for every four feet of height). On residential roofs, roof jacks and planks are required on slopes exceeding 8:12. Oklahoma contractors must ensure all workers have completed OSHA 10-hour construction safety training as a condition of CIB registration.

Oklahoma Contractor Registration — CIB

Title 59, Section 1000.1 et seq. of the Oklahoma Statutes requires all residential roofing contractors to register with the Oklahoma Construction Industries Board (CIB). Registration requires proof of general liability insurance (minimum $300,000 per occurrence), workers' compensation coverage, and completion of OSHA 10-hour training. Unregistered contractors may not pull permits and are subject to civil penalties. Homeowners who hire unregistered contractors may lose warranty protections and give their insurer grounds to deny claims related to that work.

Oklahoma Storm Chaser Law

Oklahoma law (HB 1628) regulates out-of-state contractors who solicit roofing work following a declared disaster. Such contractors must register with the CIB within 10 days of beginning work in Oklahoma, carry the same insurance requirements as resident contractors, and provide a written contract with a 3-business-day right of rescission. Violations are subject to civil penalties of up to $10,000 per occurrence and may result in criminal charges for repeat offenders.

ADA & Accessibility — Roof Access

Where rooftop equipment requires regular maintenance access, IBC Chapter 11 and the Americans with Disabilities Act (ADA) may require accessible routes to rooftop mechanical areas on commercial buildings. This typically applies to buildings with rooftop HVAC units requiring routine service by maintenance personnel. Accessible roof hatches, stair towers, or elevator access may be required depending on the building occupancy and the frequency of required maintenance access.

Historic Preservation — SHPO Requirements

Roofing work on buildings listed on the National Register of Historic Places or contributing structures in Oklahoma historic districts must comply with the Secretary of the Interior's Standards for Rehabilitation. The Oklahoma State Historic Preservation Office (SHPO) reviews proposed roofing materials and methods on historic structures. In-kind replacement with historically appropriate materials is generally required; modern synthetic materials may be approved if they match the visual character of the original. Federal historic tax credits require SHPO approval of all exterior work.

07
IBC Chapter 15 / FM Global / NRCA

Commercial Roofing Standards

Commercial roofing in Oklahoma is governed by IBC Chapter 15, FM Global loss prevention standards, and NRCA industry guidelines. Commercial systems — including built-up roofing, single-ply membranes, modified bitumen, and metal panel — carry distinct code requirements, wind uplift testing protocols, and inspection obligations that differ substantially from residential work.

IBC Chapter 15 — Roof Assemblies & Rooftop Structures

IBC Chapter 15 is the primary commercial roofing code. Section 1503 requires positive drainage on all roof surfaces. Section 1504 governs wind resistance of roof coverings — commercial assemblies must be tested per ASTM E1592 or FM 4474 and meet the design wind pressures calculated for the building's location, height, and exposure category. Section 1507 lists approved roofing materials and their installation standards by system type. Section 1511 governs re-roofing: commercial re-roofing must comply with current code for the affected area, and existing roofing may remain in place only if it is structurally sound and the total assembly does not exceed the allowable dead load.

FM Global — Loss Prevention Standards

FM Global Property Loss Prevention Data Sheets are widely required by commercial property insurers in Oklahoma. FM 1-29 (Roof Deck Securement) and FM 1-49 (Perimeter Flashing) establish wind uplift resistance requirements for commercial roof decks and edge metal. FM 4470 and FM 4471 cover single-ply membrane systems. FM-approved assemblies are listed in the RoofNav database and must be installed per the FM approval listing to maintain insurance compliance. Many Oklahoma commercial property policies require FM-approved assemblies in wind zones above 115 mph.

NRCA Guidelines for Commercial Roofing

The National Roofing Contractors Association (NRCA) Roofing Manual series — covering membrane roofing, metal panel systems, and steep-slope systems — provides the industry standard of care for commercial installation. NRCA details are referenced in manufacturer warranties and are used as the benchmark in construction defect litigation. Oklahoma commercial contractors should follow NRCA details for edge metal, penetration flashings, expansion joints, and field seams. NRCA membership and adherence to NRCA guidelines is a factor in CIB contractor registration and bonding.

Single-Ply Membrane Systems — TPO, EPDM, PVC

Single-ply membranes are the dominant commercial roofing system in Oklahoma. TPO (ASTM D6878) is the most common, valued for heat-weldable seams and reflectivity. EPDM (ASTM D4637) offers superior UV and ozone resistance. PVC (ASTM D4434) provides chemical resistance for restaurant and industrial applications. All single-ply systems must be installed per manufacturer specifications and the applicable ASTM standard. Seam widths, overlap dimensions, and fastener spacing are critical — deviations void manufacturer warranties and may fail FM uplift requirements.

Built-Up Roofing (BUR) Systems

Built-up roofing (BUR) consists of alternating layers of bitumen and reinforcing felts, topped with aggregate surfacing or a cap sheet. BUR systems must comply with ASTM D312 (asphalt) or ASTM D312 Type III/IV for Oklahoma's temperature range. Oklahoma's summer heat — regularly exceeding 100°F — requires Type III or Type IV asphalt to prevent slippage. BUR systems on slopes greater than 1/2:12 require back-nailing of felts per NRCA guidelines. Aggregate surfacing must be embedded in a flood coat of hot asphalt at a minimum rate of 400 lbs per square.

Modified Bitumen Systems

Modified bitumen (mod-bit) systems use polymer-modified asphalt in factory-fabricated sheets. APP (atactic polypropylene) and SBS (styrene-butadiene-styrene) are the two modifier types. APP sheets are torch-applied; SBS sheets may be torch-applied, hot-mopped, or cold-adhesive applied. ASTM D6163 (SBS) and ASTM D6222 (APP) govern material properties. Oklahoma's hail exposure makes granule-surfaced cap sheets preferable over smooth-surfaced for impact resistance. Two-ply systems (base sheet + cap sheet) are the minimum for commercial applications.

Metal Panel Roofing — Commercial

Commercial metal panel roofing must comply with IBC Section 1507.4 and AISI S100 (North American Specification for Cold-Formed Steel). Standing seam metal panels (SSM) are the preferred system for Oklahoma commercial applications due to superior wind uplift resistance — SSM systems can achieve FM 1-90 or higher ratings. Exposed fastener panels require EPDM-gasketed fasteners and are limited to slopes of 3:12 or greater. All metal panels must be installed with thermal movement provisions — fixed-point attachment with floating clips — to prevent oil-canning and fastener pullout from thermal cycling.

Wind Uplift Testing & Compliance

Commercial roofing assemblies in Oklahoma must meet wind uplift pressures calculated per ASCE 7-22 Chapter 30. Corner, edge, and field zones have different uplift requirements — corner zones typically require 2–3× the field zone pressure resistance. Assemblies must be tested per ASTM E1592 (metal panels), FM 4474 (mechanically attached membranes), or FM 4470 (adhered membranes). The tested assembly — including deck type, insulation, fastener pattern, and membrane — must match the installed assembly exactly. Substitutions require re-testing or engineering analysis.

Commercial Re-Roofing — IBC Section 1511

IBC Section 1511 governs commercial re-roofing in Oklahoma. Existing roofing may be recovered (new membrane over existing) only if: the existing membrane is structurally sound, the total assembly does not exceed the allowable dead load, and the existing system has no more than one existing re-cover. If the existing roof has two or more layers, full tear-off is required. Re-roofing triggers compliance with current energy code (IECC) insulation requirements for the affected area. Structural assessment of the deck is required before re-roofing on buildings over 20 years old.

Rooftop Equipment & Structural Loading

IBC Section 1604 and ASCE 7-22 Chapter 4 govern rooftop equipment loads on commercial buildings. HVAC units, solar arrays, cooling towers, and mechanical screens must be accounted for in the structural design. Oklahoma's wind loads require rooftop equipment to be anchored against both uplift and lateral forces. Equipment curbs must be a minimum of 8 inches above the finished roof surface per IMC Section 304. Penetrations for equipment supports must be flashed with pre-manufactured curb flashings or custom sheet metal fabricated to SMACNA standards.

08
NRCA / IBC 1502 / IECC

Flat & Low-Slope Roofing

Low-slope roofing (slopes less than 2:12) and flat roofing present unique design, drainage, and performance challenges in Oklahoma's climate — extreme heat, hail, and occasional freeze-thaw cycles all affect membrane selection and detailing. This section covers the specific code requirements, material standards, and best practices that apply to flat and low-slope systems.

Definition & Slope Requirements

IBC and IRC define low-slope roofing as any roof with a slope less than 2:12 (9.5°). Flat roofing typically refers to slopes of 1/4:12 to 1/2:12 — the minimum required for positive drainage. True zero-slope ('dead flat') roofs are not permitted under IBC Section 1503.4, which requires all roofs to drain within 48 hours of rainfall. Slopes below 1/4:12 require structural analysis to confirm the deck can support ponding loads without deflection that creates additional ponding (progressive ponding failure).

Drainage Design — IBC 1502 & IPC 1106

Positive drainage is the single most critical design requirement for flat roofing in Oklahoma. IBC Section 1502 requires primary roof drains sized per IPC Table 1106.2 based on the roof area and local design rainfall intensity. Oklahoma City design rainfall is 4.0 in/hr (100-year, 1-hour event); Tulsa is 3.8 in/hr. Secondary (overflow) drains or scuppers are mandatory and must be sized to handle the full design rainfall if primary drains are blocked. Overflow scuppers must be located 2 inches above the primary drain level and must discharge visibly to alert building occupants to primary drain failure.

Tapered Insulation Systems

Tapered insulation is the preferred method for achieving positive drainage on structurally flat decks. Polyisocyanurate (polyiso) tapered panels are the most common product, available in slopes from 1/8:12 to 1:12. Tapered systems must be designed by a roofing professional using a drainage plan that accounts for drain locations, crickets, and saddles. Minimum slope at any point in the tapered system must be 1/4:12. Oklahoma's temperature extremes require polyiso insulation to be covered with a cover board (minimum 1/2-inch gypsum or wood fiber) to prevent thermal shock damage to the membrane.

Membrane Selection for Oklahoma Climate

Oklahoma's climate — hot summers (100°F+), hail, UV exposure, and occasional ice — demands careful membrane selection. TPO (60-mil minimum for Oklahoma hail exposure) offers heat-weldable seams and good reflectivity. EPDM (60-mil minimum, fully adhered preferred over ballasted in high-wind zones) provides excellent UV resistance. PVC is preferred for chemical exposure applications. Ballasted EPDM systems are generally not recommended in Oklahoma wind zones above 115 mph without engineering analysis, as ballast can become projectiles in high-wind events. All membranes must carry a minimum 20-year manufacturer warranty for commercial applications.

Insulation Requirements — IECC Compliance

The IECC requires minimum R-20 continuous insulation (ci) for low-slope commercial roofs in Climate Zone 3 (most of Oklahoma), or R-20 + R-3.8 ci for above-deck insulation assemblies. Polyisocyanurate is the most common insulation, but its R-value degrades at low temperatures — IECC allows a 0.85 derate factor for polyiso in Climate Zone 3. Two-layer insulation installation (joints offset 6 inches minimum) is required to eliminate thermal bridging at board joints. Insulation must be mechanically fastened or adhered per FM Global requirements for the applicable wind zone.

Penetration Flashing Details

Penetration flashings are the most common source of flat roof leaks in Oklahoma. All pipe penetrations must use pre-manufactured pipe boots or custom-fabricated sheet metal flashings extending a minimum of 8 inches above the finished roof surface. Pitch pockets are not permitted on new construction under NRCA guidelines and are discouraged on re-roofing due to maintenance requirements. Equipment curbs must be a minimum of 8 inches above the membrane surface. All penetration flashings must be fully adhered to the membrane with compatible adhesive — mechanical fastening alone is not acceptable for low-slope applications.

Edge Metal & Perimeter Flashings

Edge metal on low-slope roofs must comply with ANSI/SPRI ES-1 (wind design standard for edge systems) and FM 1-49 (perimeter flashing). Oklahoma's wind zones require edge metal tested to the design wind pressure for the building's corner and edge zones — typically 1.5× to 2× the field zone pressure. Gravel stops, fascia, and coping must be mechanically fastened at intervals determined by the wind uplift calculation. Continuous cleat attachment is required for coping on buildings over 30 feet in height. All edge metal must be fabricated from minimum 24-gauge galvanized steel, aluminum, or copper.

Roof Deck Requirements for Low-Slope

Steel deck is the most common substrate for commercial low-slope roofing in Oklahoma. IBC Table 1507.2.2 specifies minimum deck requirements by roofing system type. Steel deck must comply with SDI (Steel Deck Institute) standards — minimum 22-gauge for roof deck. Concrete decks must be primed before membrane application. Wood decks (plywood or OSB) require a minimum 15/32-inch thickness and must be dry at time of roofing. Lightweight insulating concrete (LWIC) decks require special fastener pullout testing before mechanically attached membrane systems are specified. All decks must be inspected for deflection, moisture, and structural integrity before re-roofing.

Ponding Water & Structural Concerns

Ponding water is a critical concern on Oklahoma flat roofs. IBC Section 1611 requires structural analysis for ponding on any roof with a slope less than 1/4:12 or where deflection under load could create additional ponding. The analysis must demonstrate that the roof structure is stable under the maximum ponding load — typically 5.2 psf per inch of water depth. Oklahoma's intense rainfall events (4+ inches/hour) can overwhelm drainage systems and create temporary ponding loads exceeding 20 psf. Structural engineers must account for combined snow, rain, and ponding loads in northeastern Oklahoma counties.

Maintenance & Inspection Requirements

Oklahoma commercial building owners are responsible for maintaining flat roofs in watertight condition under IBC Section 101.3 and local property maintenance codes. NRCA recommends semi-annual inspections (spring and fall) for all low-slope systems. Post-storm inspections are required after any hail event of 3/4 inch or larger. Inspection records should document membrane condition, drain condition, flashing integrity, and any repairs made. Insurance carriers increasingly require documented maintenance records as a condition of coverage for commercial flat roofs in Oklahoma's high-hail-frequency zones.

09
IBC 1507.4 / AISI / ASTM / MCA

Metal Roofing Standards & Types

Metal roofing is one of the fastest-growing segments in both residential and commercial Oklahoma roofing — valued for longevity, wind resistance, and hail performance. Multiple system types exist, each governed by distinct material standards, installation requirements, and performance ratings. This section covers every major metal roofing type and the codes, standards, and Oklahoma-specific considerations that apply to each.

Governing Codes & Standards Overview

Metal roofing in Oklahoma is governed by IBC Section 1507.4 (metal roof panels) and 1507.5 (metal roof shingles) for commercial applications, and IRC Section R905.10 (metal panels) and R905.11 (metal shingles) for residential. Material standards are set by ASTM International and the American Iron and Steel Institute (AISI S100). The Metal Construction Association (MCA) publishes installation guidelines and technical bulletins that are widely referenced as the industry standard of care. All metal roofing must carry a UL 790 or ASTM E108 fire rating and must be tested for wind uplift per ASTM E1592 or FM 4474.

Standing Seam Metal Panels (SSM)

Standing seam is the premium metal roofing system for both residential and commercial applications in Oklahoma. Panels interlock at raised seams (1 to 3 inches high) with concealed fasteners, eliminating exposed fastener penetrations through the metal. SSM systems achieve the highest wind uplift ratings — FM 1-90 and above — making them the preferred choice in Oklahoma's high-wind zones. Minimum material: 24-gauge Galvalume-coated steel (ASTM A792) or 0.032-inch aluminum (ASTM B209). Thermal movement is accommodated by floating clip attachment — fixed-point clips are used only at one end of each panel run. Minimum slope: 1/4:12 for structural SSM panels with factory-applied sealant; 3:12 for architectural SSM panels.

Exposed Fastener Metal Panels (R-Panel / 5-V Crimp)

Exposed fastener panels — including R-panel, PBR panel, and 5-V crimp — are the most common metal roofing system on Oklahoma agricultural, industrial, and light commercial buildings. Fasteners penetrate the metal panel and seal with EPDM-gasketed screws. Minimum material: 26-gauge Galvalume steel (ASTM A792) for roofing applications. Minimum slope: 3:12 per IBC 1507.4.2 and IRC R905.10.2 — shallower slopes require factory-applied sealant at all laps and fastener locations. Exposed fastener systems require periodic re-fastening as EPDM gaskets degrade — typically every 15 to 20 years in Oklahoma's UV and temperature environment. Not recommended for slopes below 2:12 without engineering analysis.

Metal Roof Shingles & Tiles

Metal shingles and tiles replicate the appearance of asphalt shingles, wood shakes, slate, or clay tile while providing metal's durability. Governed by IBC Section 1507.5 and IRC R905.11. Minimum material: 26-gauge steel or 0.024-inch aluminum. Metal shingles must be installed over solid sheathing with a minimum No. 30 felt underlayment or self-adhering modified bitumen underlayment. Minimum slope: 3:12. Metal shingles are particularly popular in Oklahoma for re-roofing over existing asphalt shingles — the interlocking panel design provides Class 4 impact resistance (UL 2218) and Class A fire rating, qualifying for insurance discounts in most Oklahoma counties.

Stone-Coated Steel Roofing

Stone-coated steel panels combine a Galvalume steel substrate with an acrylic-bonded stone chip coating, providing the appearance of tile or shake with metal's structural performance. Common profiles include shake, tile, and shingle. Minimum substrate: 26-gauge Galvalume (ASTM A792 AZ50 coating). Stone-coated steel systems typically achieve Class 4 impact resistance (UL 2218) and Class A fire rating. In Oklahoma, stone-coated steel is valued for its combination of hail resistance, wind resistance (tested to 120+ mph), and aesthetic flexibility. Installation requires manufacturer-specific clip and fastener systems — substitutions void the warranty and may affect UL and FM ratings.

Corrugated Metal Roofing

Corrugated metal panels — with their distinctive wave profile — are used primarily on agricultural, industrial, and accessory structures in Oklahoma. Standard corrugated profiles (1.25-inch corrugation at 2.67-inch pitch) are governed by ASTM A653 (galvanized) or ASTM A792 (Galvalume). Minimum gauge: 29-gauge for spans up to 24 inches; 26-gauge for spans up to 36 inches. Corrugated panels are not recommended for occupied residential or commercial buildings in Oklahoma wind zones above 115 mph without engineering analysis — the exposed fastener attachment and lap seam design provide lower wind uplift resistance than standing seam or interlocking panel systems.

Metal Material Standards — Steel

Steel is the dominant metal roofing material in Oklahoma. Galvalume (ASTM A792) — a zinc-aluminum alloy coating — provides superior corrosion resistance compared to galvanized (ASTM A653) and is the standard for roofing applications. Minimum Galvalume coating: AZ50 (0.50 oz/ft²) for painted panels; AZ55 for bare (unpainted) applications. G90 galvanized (0.90 oz/ft²) is acceptable for painted panels but not recommended for bare applications in Oklahoma's humid climate. Steel panels must be factory-painted with a minimum 70% PVDF (Kynar) fluoropolymer coating for warranty compliance — polyester coatings have shorter service lives in Oklahoma's UV environment and are not recommended for roofing.

Metal Material Standards — Aluminum & Copper

Aluminum roofing (ASTM B209) is naturally corrosion-resistant and does not require a protective coating, making it suitable for coastal and high-humidity applications. Minimum thickness: 0.032 inch for panels; 0.024 inch for shingles. Aluminum is lighter than steel (approximately 1/3 the weight) but has a higher thermal expansion coefficient — thermal movement provisions are critical. Copper roofing (ASTM B370) is the premium architectural metal roofing material, used on historic buildings, churches, and high-end residential projects. Minimum thickness: 16 oz/ft² (0.0216 inch) for standing seam; 20 oz/ft² for flat seam. Copper must not contact aluminum, galvanized steel, or pressure-treated lumber — galvanic corrosion will occur. Use lead, neoprene, or copper isolation strips at all dissimilar metal contacts.

Hail Performance & Impact Ratings

Oklahoma's severe hail climate makes impact resistance the primary performance criterion for metal roofing selection. UL 2218 Class 4 is the highest impact rating — achieved by dropping a 2-inch steel ball from 20 feet without cracking or splitting the panel. FM 4473 is the equivalent FM Global standard. Most 24-gauge and heavier steel standing seam panels achieve Class 4. Exposed fastener panels in 26-gauge may achieve Class 3 or 4 depending on profile. Aluminum panels are more susceptible to cosmetic denting from hail than steel — 0.040-inch or heavier aluminum is recommended in Oklahoma hail zones. Stone-coated steel and metal shingles with Class 4 ratings qualify for insurance premium discounts of 20–30% with most Oklahoma carriers.

Wind Uplift Performance

Metal roofing must resist the design wind pressures calculated per ASCE 7-22 for the building's location, height, and exposure. Standing seam systems with concealed floating clips achieve the highest uplift ratings — FM 1-90 (90 psf) and above. Exposed fastener systems are limited by fastener pullout strength in the deck — typically FM 1-60 to 1-75 for 26-gauge panels on plywood decks. In Oklahoma's high-wind counties (design speeds above 130 mph), standing seam is strongly recommended over exposed fastener for all occupied structures. Edge metal and trim must be independently tested per ANSI/SPRI ES-1 — the panel system rating does not cover edge conditions.

Thermal Movement & Oil-Canning

Metal roofing expands and contracts significantly with Oklahoma's temperature swings — from -10°F winter lows to 110°F+ summer highs, a range of 120°F or more. Steel expands approximately 0.0000065 inch per inch per °F; aluminum expands at nearly twice that rate. A 40-foot steel panel run experiences approximately 0.37 inches of movement across a 120°F temperature range. Fixed-point attachment without thermal movement provisions causes oil-canning (visible waviness in the panel flat), fastener pullout, and seam failure. Standing seam floating clips, slotted fastener holes in exposed fastener panels, and proper panel length limits (typically 40 feet maximum for steel, 20 feet for aluminum) are required to manage thermal movement.

Underlayment Requirements for Metal Roofing

Metal roofing requires specific underlayment to prevent condensation damage, noise, and corrosion. IRC R905.10.3 requires a minimum No. 30 felt underlayment under metal panels on slopes 3:12 and above. Self-adhering modified bitumen underlayment (ASTM D1970) is required in valleys and at eaves. High-temperature underlayment (rated to 250°F minimum) is required under metal roofing in Oklahoma — standard felt and many synthetic underlayments can fail under metal panels in summer heat. Vented underlayment products (with embossed or waffled surfaces) are recommended to allow moisture vapor to escape and prevent corrosion of the metal panel underside. Felt underlayment must not be used under bare (unpainted) Galvalume — the sulfur compounds in felt accelerate Galvalume corrosion.

Flashing & Trim Standards

Metal roofing flashings and trim must be fabricated from compatible materials to prevent galvanic corrosion. Steel panel systems use Galvalume or galvanized steel trim; aluminum systems use aluminum trim. Copper trim must never contact steel or aluminum. All trim and flashing must be factory-painted to match the panel system — field-painted trim is not acceptable for warranty compliance. Closure strips (foam or rubber) at eave and ridge must be profile-specific — generic foam closures allow wind-driven rain infiltration and pest entry. Ridge caps must be mechanically fastened at maximum 12-inch spacing and sealed with butyl tape at all laps. Valley flashings must extend a minimum of 8 inches under each panel side.

Oklahoma-Specific Considerations

Oklahoma's climate presents several metal roofing challenges beyond wind and hail. Thermal shock from rapid temperature changes (afternoon thunderstorms dropping temperatures 30°F in minutes) stresses panel coatings and sealants — PVDF coatings outperform polyester in this environment. Red clay dust common in western Oklahoma is mildly abrasive and can accelerate coating wear on low-slope metal panels. Ice damming in northeastern Oklahoma (Tulsa and above) requires ice and water shield at eaves and in valleys even on metal roofing. Wildfire ember resistance is increasingly important in rural Oklahoma — Class A fire-rated metal roofing is strongly recommended in the Wildland-Urban Interface (WUI) zones designated by the Oklahoma Forestry Services.

10
CIB Regulations

Oklahoma Construction Industries Board

The Oklahoma Construction Industries Board (CIB) is the state agency responsible for licensing, registering, and regulating construction contractors — including roofing contractors — under Title 59, Sections 1000.1 through 1000.30 of the Oklahoma Statutes. Compliance with CIB requirements is mandatory for all residential roofing contractors operating in Oklahoma and is a prerequisite for pulling building permits.

Statutory Authority & Jurisdiction

The CIB operates under Title 59, Section 1000.1 et seq. of the Oklahoma Statutes. The Board has jurisdiction over all residential construction contractors, including roofing contractors performing work on one- and two-family dwellings and townhouses regulated by the IRC. Commercial roofing contractors are regulated separately under the IBC and are not subject to CIB residential registration, though they must comply with all applicable licensing and insurance requirements. The CIB has authority to investigate complaints, conduct hearings, impose civil penalties, and revoke or suspend registrations.

Residential Roofing Contractor Registration

All contractors performing residential roofing work in Oklahoma must register with the CIB before soliciting, bidding, or performing work. Registration is not optional — it is a legal requirement. An unregistered contractor who performs residential roofing work is subject to civil penalties of up to $10,000 per occurrence. Homeowners who knowingly hire an unregistered contractor may lose warranty protections on materials installed and give their insurer grounds to deny claims related to that work. Registration must be renewed annually and is tied to the contractor's insurance and training status.

Insurance Requirements

CIB registration requires proof of active general liability insurance with a minimum limit of $300,000 per occurrence and $600,000 aggregate. Workers' compensation insurance is required for any contractor with employees — sole proprietors with no employees may file a workers' compensation exemption. Certificates of insurance must name the CIB as a certificate holder and must be kept current throughout the registration period. A lapse in insurance coverage automatically suspends the contractor's registration. Contractors must provide a current certificate of insurance to homeowners upon request before signing a contract.

OSHA 10-Hour Training Requirement

All CIB-registered roofing contractors and their on-site supervisors must complete the OSHA 10-Hour Construction Safety Training course. This requirement applies to the registrant and to any employee who serves as a job-site supervisor. OSHA 10 cards must be presented to the CIB at registration and renewal. The training covers fall protection, ladder safety, electrical hazards, struck-by hazards, and caught-in/between hazards — the four leading causes of construction fatalities. Contractors who have not completed OSHA 10 training may not supervise residential roofing work in Oklahoma.

Written Contract Requirements

CIB regulations require residential roofing contractors to provide a written contract before beginning any work. The contract must include: the contractor's full legal name, CIB registration number, and contact information; a detailed description of the scope of work; the total contract price and payment schedule; the start and estimated completion date; a description of materials to be used including manufacturer and product name; and the contractor's insurance information. Contracts for work exceeding $2,500 must also include a notice of the homeowner's right to cancel within 3 business days if the contract was solicited at the homeowner's residence.

Right of Rescission — Door-to-Door Solicitation

Under the Oklahoma Consumer Protection Act (15 O.S. § 751 et seq.) and CIB regulations, homeowners have a 3-business-day right to cancel any residential roofing contract that was solicited at their home — including contracts signed after a storm when a contractor knocked on the door. The contractor must provide a written notice of this right at the time of signing. Failure to provide the rescission notice is a violation of both the Consumer Protection Act and CIB regulations and may void the contract entirely. This right applies regardless of whether the homeowner signed the contract voluntarily.

Oklahoma Storm Chaser Law

Oklahoma has enacted legislation (HB 1628) regulating out-of-state contractors who solicit roofing work following a declared disaster or severe weather event. Such contractors must register with the CIB within 10 days of beginning work in Oklahoma, carry the same insurance minimums as resident contractors, and provide a written contract with the 3-business-day right of rescission. The law applies to any contractor whose principal place of business is outside Oklahoma. Violations are subject to civil penalties of up to $10,000 per occurrence. Repeat violations may result in criminal charges. The CIB maintains a list of registered storm-chaser contractors on its website.

Deductible Waiver Prohibition

It is illegal under Oklahoma law (OAC 365:15-3-1 and 36 O.S. § 1435.1) for a roofing contractor to offer, advertise, or agree to waive, absorb, rebate, or pay a homeowner's insurance deductible as an inducement to sign a roofing contract. This prohibition applies regardless of how the arrangement is structured — whether framed as a 'discount,' 'credit,' 'upgrade,' or any other term. A contractor who waives a deductible commits insurance fraud. A homeowner who knowingly participates may also face consequences including policy cancellation. Any contractor who offers to 'cover your deductible' should be reported to the CIB and the Oklahoma Insurance Department.

Permit Pulling Requirements

Only CIB-registered contractors may pull building permits for residential roofing work in Oklahoma. A homeowner may pull their own permit for work they personally perform on their own primary residence, but may not pull a permit on behalf of a contractor. Contractors who perform permitted work without a valid CIB registration are subject to stop-work orders, civil penalties, and potential criminal charges. The authority having jurisdiction (AHJ) — typically the city or county building department — verifies CIB registration status before issuing permits. Contractors must display their CIB registration number on all vehicles, signage, and advertising used in connection with residential roofing work.

Subcontractor Compliance

The registered contractor of record is responsible for ensuring that all subcontractors performing work on a residential roofing project are also CIB-registered and carry the required insurance. Using an unregistered subcontractor does not transfer liability to the subcontractor — the registered contractor remains fully responsible for the work and for any violations. Subcontractor insurance certificates must be obtained and retained by the general contractor before work begins. Failure to verify subcontractor registration is a violation of CIB regulations and may result in suspension of the general contractor's registration.

Complaint Filing & Disciplinary Process

Homeowners, other contractors, or any member of the public may file a complaint against a CIB-registered contractor by submitting a written complaint to the CIB at its Oklahoma City office or online at ok.gov/cib. The CIB investigates complaints, may conduct hearings, and has authority to impose civil penalties up to $10,000 per violation, require restitution, suspend or revoke registrations, and refer criminal matters to the district attorney. Complaints against unregistered contractors are also accepted — the CIB will investigate and may pursue civil penalties even against contractors who never registered. Contractors have the right to a hearing before any disciplinary action becomes final.

Verifying Contractor Registration

Before signing any residential roofing contract, homeowners and general contractors should verify the roofing contractor's CIB registration status online at ok.gov/cib using the contractor's name, business name, or registration number. A valid registration confirms the contractor has met the insurance, training, and legal requirements to perform residential roofing work in Oklahoma. Registration status can change — a contractor who was registered at the time of bidding may have a lapsed registration by the time work begins. Verify registration immediately before signing the contract and again before the first payment is made.

Lien Waiver Requirements

Oklahoma's mechanic's lien law (42 O.S. § 141 et seq.) gives roofing contractors, subcontractors, and material suppliers the right to file a lien against a property if they are not paid. Homeowners should require a lien waiver from the general contractor and all subcontractors and material suppliers upon each payment. A final lien waiver from all parties should be obtained before the final payment is released. CIB regulations require contractors to provide lien waivers upon request. Failure to provide lien waivers after payment is a violation of CIB regulations and may be grounds for a complaint. Title companies will require lien waivers before closing on a property where recent roofing work was performed.

Advertising & Misrepresentation Prohibitions

CIB regulations prohibit roofing contractors from misrepresenting their registration status, insurance coverage, certifications, or qualifications in any advertising, solicitation, or contract. Contractors may not claim to be FORTIFIED-certified, HAAG-certified, or hold any other credential they do not actually possess. Contractors may not use another contractor's CIB registration number. All advertising — including yard signs, vehicle wraps, social media, and websites — must display the contractor's CIB registration number. Misrepresentation of credentials is a violation of both CIB regulations and the Oklahoma Consumer Protection Act and may result in registration revocation and civil penalties.

11
Exam Study Materials

Oklahoma Commercial Roofing Exam — Reference Manuals

The Oklahoma Construction Industries Board (CIB) commercial roofing contractor examination is based on a defined set of reference manuals covering building codes, roofing standards, safety regulations, and installation specifications. Candidates must be familiar with all listed documents. The following is the complete reference manual list as required for the Oklahoma commercial roofing examination.

International Building Code (IBC) — Current Edition

Published by the International Code Council (ICC). Oklahoma's current adopted edition is the 2024 IBC (effective September 14, 2026); the prior cycle was the 2018 IBC (effective September 14, 2021). The IBC is the primary building code governing commercial construction in Oklahoma as adopted by the OUBCC. For roofing, Chapter 15 (Roof Assemblies and Rooftop Structures) is the core reference, covering roofing materials, slope requirements, underlayment, flashing, drainage, and re-roofing. Chapter 16 (Structural Design) and Chapter 17 (Special Inspections) are also tested. Candidates must know IBC Sections 1501 through 1521 in detail. Confirm with the CIB which edition is tested on the current exam. The IBC is published by ICC and available at iccsafe.org.

International Residential Code (IRC) — Current Edition

Published by the International Code Council (ICC). Oklahoma's current adopted edition is the 2024 IRC (effective September 14, 2026); the prior cycle was the 2018 IRC (effective September 14, 2022). The IRC governs one- and two-family dwellings and townhouses. Chapter 9 (Roof Assemblies) covers asphalt shingles, metal roofing, tile, slate, wood shingles, and built-up roofing for residential structures. IRC R905 through R908 are the primary roofing sections. Candidates must understand the differences between IRC and IBC requirements and know which code applies to which occupancy type. Confirm with the CIB which edition is tested on the current exam. The IRC is published by ICC and available at iccsafe.org.

ASCE 7-22: Minimum Design Loads and Associated Criteria for Buildings and Other Structures

Published by the American Society of Civil Engineers (ASCE). ASCE 7-22 is the structural load standard referenced by both the IBC and IRC for wind, snow, seismic, and rain loads. For roofing, Chapter 26 (Wind Loads — General Requirements), Chapter 27 (Wind Loads on Buildings — MWFRS), and Chapter 30 (Wind Loads — Components and Cladding) are the primary exam topics. Candidates must understand how to read ASCE 7 wind speed maps, determine exposure categories, and apply component and cladding (C&C) pressure coefficients to roofing systems. Available at asce.org.

NRCA Roofing Manual: Membrane Roof Systems

Published by the National Roofing Contractors Association (NRCA). This manual covers low-slope membrane roofing systems including EPDM, TPO, PVC, modified bitumen, and built-up roofing (BUR). It provides the industry standard of care for design, detailing, and installation of commercial membrane roofing. Exam topics include membrane attachment methods, insulation requirements, edge metal details, penetration flashings, drain design, and re-roofing over existing systems. The NRCA Roofing Manual is the primary commercial roofing installation reference. Available at nrca.net.

NRCA Roofing Manual: Metal Panel and SPF Roof Systems

Published by the National Roofing Contractors Association (NRCA). This volume covers structural and architectural metal panel roofing systems including standing seam, R-Panel, and through-fastened systems, as well as spray polyurethane foam (SPF) roofing. Exam topics include panel profiles, attachment methods, thermal movement provisions, underlayment requirements, flashing details, and coating systems. Candidates must understand the difference between structural and architectural metal panels and their respective code requirements. Available at nrca.net.

NRCA Roofing Manual: Steep-Slope Roof Systems

Published by the National Roofing Contractors Association (NRCA). This volume covers steep-slope roofing systems including asphalt shingles, metal roofing, tile, slate, and wood shingles/shakes. Exam topics include underlayment requirements, fastening schedules, valley flashing, hip and ridge details, ventilation requirements, and ice and water shield application. Candidates must know NRCA details for all major steep-slope systems and understand how NRCA details relate to IRC requirements. Available at nrca.net.

SMACNA Architectural Sheet Metal Manual, 8th Edition

Published by the Sheet Metal and Air Conditioning Contractors' National Association (SMACNA). The SMACNA Architectural Sheet Metal Manual is the definitive reference for sheet metal flashing, coping, edge metal, gutters, downspouts, and expansion joints in roofing applications. Exam topics include coping cap design, through-wall flashing, counterflashing, scupper design, gutter sizing, and expansion joint details. SMACNA details are referenced in both the IBC and NRCA manuals and are used as the standard of care in construction defect litigation. Available at smacna.org.

ANSI/SPRI ES-1: Wind Design Standard for Edge Systems Used with Low Slope Roofing

Published by the Single Ply Roofing Industry (SPRI). ANSI/SPRI ES-1 is the wind design standard for edge metal systems — fascia, coping, and gravel stops — used with low-slope roofing. It is referenced in IBC Section 1504.5 and is required for all commercial low-slope roofing edge metal design. Exam topics include the ES-1 test protocol, edge metal classification (RE, CE, and GS), and how to specify compliant edge metal for a given wind speed and building height. Candidates must understand that the membrane system wind rating does not cover edge conditions — edge metal must be independently rated per ES-1.

FM Global Property Loss Prevention Data Sheets

Published by FM Global (Factory Mutual). FM Global data sheets — particularly FM 1-28 (Wind Design), FM 1-29 (Roof Deck Securement), FM 1-49 (Perimeter Flashing), FM 1-52 (Field Uplift Testing), and FM 1-90 through FM 1-180 (wind uplift classifications) — are the insurance industry standard for commercial roofing wind resistance. Many Oklahoma commercial building owners and insurers require FM-rated roofing assemblies. Exam topics include FM wind uplift ratings, the FM approval mark, and how FM data sheets relate to IBC wind load requirements. Available at fmglobal.com.

OSHA 29 CFR Part 1926 — Construction Industry Safety Standards

Published by the Occupational Safety and Health Administration (OSHA). Subpart R (Steel Erection), Subpart Q (Concrete and Masonry), and most importantly Subpart M (Fall Protection) are the primary roofing safety references. 29 CFR 1926.502 (Fall Protection Systems Criteria) and 1926.503 (Training Requirements) are heavily tested. Candidates must know the 6-foot fall protection trigger height for residential construction and the 15-foot trigger for leading edge work, guardrail specifications, personal fall arrest system requirements, and safety monitoring system rules. Available at osha.gov.

International Energy Conservation Code (IECC) — Current Edition

Published by the International Code Council (ICC). Oklahoma's current adopted edition is the 2024 IECC (effective September 14, 2026). The IECC governs the energy performance of building envelopes including roofing systems. For commercial roofing, IECC C402 (Building Envelope Requirements) covers roof insulation R-values, cool roof requirements, and continuous insulation specifications by climate zone. Oklahoma spans IECC Climate Zones 3 and 4. Exam topics include minimum roof insulation R-values by climate zone, cool roof solar reflectance requirements, and the interaction between roof insulation and vapor retarder requirements. Confirm with the CIB which edition is tested on the current exam. Available at iccsafe.org.

International Fire Code (IFC) — Current Edition

Published by the International Code Council (ICC). Oklahoma's current adopted edition is the 2024 IFC (effective September 14, 2026). The IFC governs fire safety requirements for roofing systems including fire classification of roofing materials (Class A, B, C), hot-work permits for torch-applied roofing, and fire watch requirements. IFC Chapter 35 (Welding and Other Hot Work) covers torch-applied modified bitumen and hot-mopped BUR systems. Exam topics include fire classification requirements by occupancy, hot-work permit procedures, fire watch duration requirements, and the interaction between IFC and IBC fire-resistance requirements for roof assemblies. Confirm with the CIB which edition is tested on the current exam. Available at iccsafe.org.

International Mechanical Code (IMC) — Current Edition

Published by the International Code Council (ICC). Oklahoma's current adopted edition is the 2024 IMC (effective September 14, 2026). The IMC governs mechanical equipment on rooftops including HVAC units, exhaust fans, and penetrations through roofing systems. IMC Chapter 9 (Venting Systems) and Chapter 5 (Exhaust Systems) are relevant to roofing contractors who must properly flash and seal mechanical penetrations. Exam topics include clearance requirements for rooftop equipment, curb height requirements for rooftop HVAC units, and proper flashing of mechanical penetrations to maintain the roof system warranty and code compliance. Confirm with the CIB which edition is tested on the current exam. Available at iccsafe.org.

ASTM Standards — Roofing Materials

Published by ASTM International. Key ASTM standards tested on the Oklahoma commercial roofing exam include: ASTM D3462 (Asphalt Shingles), ASTM D4637 (EPDM Membranes), ASTM D6878 (TPO Membranes), ASTM D6163 and D6164 (Modified Bitumen — APP and SBS), ASTM D4601 (Asphalt-Coated Glass Fiber Base Sheet), ASTM D226 (Asphalt-Saturated Felt Underlayment), ASTM D1970 (Self-Adhering Polymer Modified Bitumen Underlayment), ASTM A653 (Steel Sheet — Galvanized), ASTM A792 (Steel Sheet — Galvalume/55% Al-Zn Alloy), ASTM C1167 (Clay Roof Tile), and ASTM E108 (Fire Tests of Roof Coverings). Candidates must know the scope and key requirements of each standard. Available at astm.org.

UL Standards — Roofing

Published by Underwriters Laboratories (UL). Key UL standards for roofing include: UL 790 (Fire Tests of Roof Coverings — equivalent to ASTM E108), UL 2218 (Impact Resistance of Prepared Roof Covering Materials — the Class 1–4 hail impact rating), UL 580 (Tests for Uplift Resistance of Roof Assemblies), and UL 1897 (Uplift Tests for Roof Covering Systems). Exam topics include the UL 2218 Class 4 impact test protocol, the difference between UL 580 and FM uplift ratings, and how to read UL roofing product directories to verify listed assemblies. Available at ul.com.

Oklahoma Statutes — Title 59 (CIB) and Title 748 (OUBCC Rules)

Oklahoma-specific statutory references tested on the commercial roofing exam include Title 59, Sections 1000.1 through 1000.30 (Oklahoma Construction Industries Board Act — contractor registration, insurance requirements, penalties, and complaint procedures). OUBCC administrative rules are codified in Oklahoma Administrative Code (OAC) Title 748; CIB rules are in OAC Title 158. Candidates must understand the CIB registration requirements for commercial roofing contractors, the difference between residential and commercial contractor registration, permit requirements, and the OUBCC's authority to adopt and amend the IBC. Available at oscn.net.

NRCA Green Roof Systems Manual

Published by the National Roofing Contractors Association (NRCA). This manual covers vegetative (green) roof systems including extensive and intensive assemblies, waterproofing membranes, root barriers, drainage layers, growing media, and plant selection. As green roofs become more common on Oklahoma commercial and institutional buildings, contractors must understand the additional structural loads, waterproofing requirements, and maintenance considerations. Exam topics include the components of a green roof assembly, waterproofing membrane selection for below-grade and plaza deck applications, and the interaction between green roof assemblies and IBC structural load requirements.

IBHS FORTIFIED Commercial Standards

Published by the Insurance Institute for Business & Home Safety (IBHS). The FORTIFIED Commercial standard provides enhanced wind and hail resistance requirements for commercial buildings beyond the minimum IBC requirements. Exam topics include the FORTIFIED Commercial designation levels, enhanced fastening requirements for commercial roofing systems, edge metal requirements per ANSI/SPRI ES-1, and the interaction between FORTIFIED Commercial requirements and FM Global wind uplift ratings. Oklahoma commercial building owners increasingly require FORTIFIED Commercial compliance for insurance purposes. Available at ibhs.org.